Furuno FSV-84 User Manual

Page 64

Advertising
background image

4-2

3. Fix the power supply pcb (supplied) to the power module with four spacers (supplied).
4. Connect two VH connectors (provided on the power module) to the power supply pcb.
5. Lay the protection sheet (supplied) on top of the spacers and fasten with pan head

screws (M3×8).

6. Reattach the power module.
7. Connect between the processor unit and CS-120A as follows.

CS-120A

J201

PROCESSOR
UNIT

YEL

BRN

ORG

BRN

PPL BRN

L

E

PP

1
2
3

NN
MM
JJ
KK

1

2

3

4

5

6

BB
EE

DD

Z

24V
0V
GND

TD-H
TD-C
RD-H
RD-C

GND
DSR-C
DSR-H
DTR-H

+24V_H
+24V_C
GND

CIF_TXD_H

CIF_TXD_C

CIF_RXD_H

CIF_RXD_C

SHIELD

GND

37-core cable

10S1258

MJ-A3SPF0013-035

For CIF2

For CIF1

CS-120A

OR NMEA2/CIF2

Wiring between processor unit and CS-120A

8. Set the DIP switch on the DCON Board as follows.

Input port

DIP switch setting on DCON Board

CIF1 S3-#2:

ON

NMEA2/CIF2 S3-#3:

ON

S3

DCON Board (10P6987)

For connection to NMEA2/CIF2 port, the #8 segment of S2 on the IFES board should be
OFF (CIF).

Note:
If the CIF1 format is selected, change baud rate to 2400 bps. See CIF BAUD RATE

on page 3-8 for details.

Advertising