CM4-S Cooking Computer — Programming with Filtration

3-7


Filter Operation

The computer
must be connected
to the drain valve
safety switch in
order to function as
described at right.

To clear a
computer
programmed for
global filtering and
not connected to
the fryer’s filter
system:

• Press to

turn computer
off.

• Press button in

Frymaster
logo.

• Display

shows

CODE.

• Enter

1111

with product
keys. (On
Church’s
computers,
use 1111 to
delay filtering,
1119 to cancel
filtration. See
supplemental
Church’s
material for
instructions on
delaying and
clearing the
filter function.)

• CLR FLTR

FUNCTION
flashes in
display and
computer
displays

OFF.

Filter Operation

1. When the product count entered during the programming for

global filtering is reached, the computer will display

Filter.

2. Allow the cook cycle to complete.
3. Ensure the filter pan is properly prepared.
4. Open drain valve for a minimum of 30 seconds.
5. Display shows

Drain Open.

6. After approximately three minutes, the computer display alternates

between

Drain, Open and Fill.

7. Close drain valve. Display shows

FILL.

8. Use pump on filter system to refill fry vat.

9. Press

. Fryer returns to setpoint.


Advertising