Operational and Diagnostic Programming Codes

8-2

The computer also displays messages. Listed below are the most common and a
brief explanation of each.

Set Back

Fryer is in standby and maintaining a temperature of 250°F. Press

to exit and

bring fryer to setpoint.

DONE

Cook cycle is complete. The LED above the chosen product button will flash. Press
button under flashing LED to stop alarm.

-------

Oil temperature is near setpoint and fryer is ready to cook.

FIlter

The fryer has reached a preset number of cook cycles and requires filtering..

OPEN Drain

The frypot drain valve is open.

FILL

Filter cycle is complete and frypot drain valve is open. Close drain valve and press

to exit filter cycle and refill frypot.

HI- Temp

Fryer is above 390°F (199°C)

LOW

Fryer temperature is below 255°F (124°C)

Probe Failure

Temperature probe circuit failed.

Hi Temp Probe Failure

Hi-limit temperature has been exceeded and the hi-limit switch failed to open. The
computer will shut down the fryer.


The CM4-S also
displays
messages, some
instructional, such
as done, and
others are
diagnostic.
Common ones are
listed at right.