SPARC Enterprise M3000 Server Installation Guide • January 2009

FIGURE 3-1

UPC Connections With a Dual-Power Feed Connection

3.3.3

Connecting the Administration Console

The server is set up and statuses are displayed from the XSCF Shell through the
serial port on the XSCF unit. To connect the administration console with the serial
port, use the RS-232C cable (serial cable) supplied with the server. Also, the XSCF
Shell and the domain console (OS console) can be used with a terminal connected to
the serial port.

Note –

The XSCF board is secured on the motherboard unit (MBU) in the SPARC

Enterprise M3000 server. In this document, the XSCF board in the SPARC Enterprise
M3000 server is called the XSCF unit.

You can use any of the following devices with a DB-9 serial port as the
administration console:

ASCII terminal

Workstation

Terminal server (or a patch panel connected to a terminal server)

Personal computer

PSU#1 PSU#0

UPS#0

UPS#1

UPC1

UPC0

AC#0

AC#1

UPS cable

CB

CB

CB: Circuit breaker