FUJITSU M3000 User Manual
Page 39

Chapter 3
Installing the Server
3-5
Note –
It is possible to connect it to a LAN port via telnet or SSH access. The LAN
port has a Class B private address value, but it will not send out a packet by itself
until configured.
Note –
The modular connector (RCI connector) is not for use with a TNV circuit
connection. See Item 1 in
.
1. Confirm that the following settings have been made for software on the
administration console.
2. Prepare the serial cable.
The serial cable is supplied with the server.
3. Connect the serial port on the rear panel to the administration console.
shows the locations of the external interface port such as serial port
and LAN ports on the rear panel.
TABLE 3-1
Terminal Software Setting Values
Setting item
Value
Baud rate
9600
Data length
8 bits
Parity
None
STOP bit
1 bit
Flow control
None
Delay
Other than 0