1-9

1.7 Replace High-Limit

1. Perform Procedure 1.5, Replace Temperature

Probe, Steps 1-4.


2. Disconnect the wire harness containing the

high-limit wires.


3. Use a pin-pusher (P/N 806-4855 or P/N 807-

0928) to remove the two high-limit wires
from the wire harness connector. For split-
pot fryers, remove only the wires for the
high-limit to be replaced. Mark each wire for
re-assembly.


4. Remove the high-limit from the frypot using

an open-end wrench or other suitable tool.


5. Apply Loc-Tite PST 567 sealant to the

replacement high-limit threads.


6. Screw the replacement high-limit into the

frypot and tighten securely. DO NOT
OVERTIGHTEN.


7. Insert the replacement high-limit wires into

the proper pin-holes in the connector. The
same two pin-holes from which the defective
high-limit wires were removed.


8. Reconnect the wire harness connector.

9. Install and secure the back covers.

10. Position the fryer under the exhaust hood.















Proper element-wire routing is essential to prevent
wire chafing while raising and lowering elements.

Pin Pusher— P/N 807-0928

Place wrench here when removing and installing
high-limit.

Advertising