Electrical Requirements

MODEL VOLTAGE

PHASE

WIRE

SERVICE

MIN.

SIZE

AWG

(mm2)

AMPS PER LEG

L1 L2 L3

H14 208

3

3

6

(16)

39

39

39

H14 240

3

3

6

(16)

34

34

34

H14 480

3

3

8

(10)

17

17

17

H14 220/380

3 4 6

(16)

21

21

21

H14 240/415

3 4 6

(16)

20

20

21

H14 230/400

3 4 6

(16)

21

21

21

208 3 3 6

(16)

39

39 39

240 3 3 6

(16)

34

34 34

220/380 3

4

6 (16) 21 21 21

ALL

EPH14

SERIES

(SOLID STATE)

240/415 3

4

6 (16) 20 20 20

H17 208

3

3

6

(16)

48

48

48

H17 240

3

3

6

(16)

41

41

41

H17 480

3

3

6

(16)

21

21

21

H17 220/380

3 4 6

(16)

26

26

26

H17 240/415

3 4 6

(16)

24

24

24

` 230/400

3

4 6

(16)

25

25

25

ALL 208

3

3

6

(16)

48

48

48

240 3 3 6

(16)

41

41 41

220/380 3

4

6 (16) 26 26 26

EPH17

SERIES

(SOLID STATE)

240/415 3

4

6 (16) 24 24 24

H22 208

3

3

4

(25)

61

61

61

H22 240

3

3

4

(25)

53

53

53

H22 480

3

3

6

(16)

27

27

27

H22 220/380

3 4 6

(16)

34

34

34

H22 240/415

3 4 6

(16)

31

31

31

H22 230/400

3 4 6

(16)

32

32

32

Advertising