1.8 Replace Frypot



1. Perform Procedure 1.5, Replace Temperature Probe, Steps 1-7.

2. Perform Procedure 1.2, Replace Computer/Controller, Steps 1-6.

3. Disconnect the wire harness containing the high-limit wires.

4. Use a pin-pusher to remove the high-limit wires from the wire harness connector.

5. Remove the high-limit from the frypot.

6. Disconnect the wire-harnesses connected to the contactor box.

7. Remove the screws securing the capping piece from the fryer. Remove the capping piece and set

aside. It may be necessary to remove the wiring covers from the front of the contactor box.


8. If the fryer has a built-in filtration system, remove all the plumbing from the frypot, including

rear-flush and square-drain plumbing.


9. Remove the screws securing the frypot to the front frame of the fryer.

10. Carefully lift the frypot from the cabinet.

11. Remove the drain valve from the old frypot and install on the new frypot.

12. Apply Loc-Tite Sealant PST 567 to the high-limit threads. Install the high-limit into the new

frypot.


13. Disconnect the tilt plate springs from the old frypot.

14. Remove the securing screws from the tilt plate. Lift the tilt plate/heating element assembly from

the old frypot and install on the new frypot.


15. Follow the preceding steps in reverse to install the new frypot into the fryer.

16. NOTE: Apply Loc-Tite Sealant PST 567 to all pipefittings prior to installation.

1.9 Replace Contactor


1. Perform Procedure 1.4, Replace Temperature Probe, Steps 1-3.

2. Remove the screws securing the bottom and center rear access covers. Set the screws and covers

aside.

Advertising