7. Push the filter pan back into the fryer, positioning it

all the way to the back of the cabinet.


OPERATING THE FILTER UNIT

CAUTION

Never operate the filter unit unless the cooking oil in the fryers has been brought up

to cooking temperature.

1. To filter the cooking oil, turn the controller

OFF, then open the drain valve on the fryer
you have selected to be filtered. If necessary,
use the Fryer's Friend steel rod to clear the
drain from inside the frypot.

DANGER

Never drain more than one fryer at a time—the filter pan may overflow. When

unclogging a valve, DO NOT insert anything into the drain from the front of the fryer.

Hot oil will rush out, creating an extreme hazard.

WARNING

DO NOT hammer on the drain valve with the Fryer’s Friend. This will damage the

drain valve ball and prevent the valve from sealing securely, resulting in a leaky

valve.

WARNING

When cleaning the inside of the frypot, avoid striking the high-limit thermostat and

temperature probe or operating thermostat.