6-6

BURNERS DO NOT

LIGHT

(POWER LIGHT ON,

HEAT LIGHT ON,

TROUBLE LIGHT ON)

Verify that all drain valves are fully

closed. Verify the main gas valve is

open and the gas valve knob (non-

CE units) is ON. Place power

swtiches in OFF position, then back

ON.

Did burners

light?

Problem resolved.

Yes

Place power switches in OFF

position. Disconnect and reconnect

the flexible gas line quick-disconnect

fitting. Place power switches in ON

position.

No

Did burners

light?

Problem resolved.

Yes

Place power switches in OFF

position. Verify that combustion air
blower inlet is open and that blower

is clean. Place power switches in

ON position.

No

Did burners

light?

No

Problem resolved.

Yes

Problem is beyond scope of

operator troubleshooting. Call

FASC

No

FRYER FAILS 2ND

HIGH-LIMIT TEST

(HEAT LIGHT ON, 2ND

HI-LIMIT LIGHT OFF,

AND FRYER

CONTINUES TO HEAT IN

2ND HI-LIMIT TEST

POSITION.)

Probable cause is a defective high-

limit thermostat. Call FASC.