6-3


DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

BUT BURNERS LIGHT

Press ON/OFF switch OFF

(on Split Vat units, both
switches must be OFF).

Swap computer with another

known to be working

correctly. Press ON/OFF

switch ON.

Is fryer

operating

correctly?

False alarm. Install

computer on another

fryer and test operation.

If problem repeats,

computer is defective and

must be replaced. If not,

problem should be

investigated by

FASC.

Yes

Probable cause is a

defective ignition module.

Call FASC.

No

DISPLAY SHOWS

IGNITION FAILURE,

ALARM IS SOUNDING,

AND BURNERS WILL

NOT LIGHT

Verify that all drain

valves are fully

closed, the main gas

valve is open and the

gas valves on the

fryer are on.

Press ON/OFF switch

OFF (on Split Vat

units, both switches

must be OFF). Press

ON/OFF switch ON.

Is fryer

operating

correctly?

Problem resolved.

Yes

Probable causes are a

defective or misaligned drain

safety switch or an open

high-limit thermostat.

Call FASC.

No