6.2.3 Troubleshooting Fryers Equipped with Analog Controllers

FRYER OPERATES

PROPERLY BUT "POPS"

WHEN BURNERS LIGHT.

Problem is beyond scope of

operator troubleshooting. Call

FASC

No

Place power switches in OFF

position. Verify that combustion air

blower shutter is open and that

blower is clean. Place power

switches in ON position.

Did popping

cease?

Problem resolved.

Yes

POWER LIGHT ON,

TROUBLE LIGHT ON,

HEAT LIGHT OFF,

BURNERS DO NOT

LIGHT.

Place power switches in OFF

position. Swap controller with

another known to be working. Place

power switches ON.

Does

fryer operate

correctly?

Defective controller.

Replace.

Yes

Probable causes are loose or

broken wiring connections.

Call FASC.

No

POWER SWITCH ON,

BUT NO CONTROLLER

LIGHTS ARE LIT.

Verify that power cord is plugged

into live circuit, fryer circuit breaker

is not tripped, and hood circuit

breaker is not tripped..

If above conditions are correct,

probable causes are failed

transformer or failed controller. Call

FASC.