14. Bulk System: With the pan empty, press the (1) button (see Figure 130).


Figure 130

15. Bulk System: The computer displays

Disengage dispose

switch. Place the RTI door switch in the center position (see Figure
131).

Figure 131

16. Bulk System: Press the (1) button to disengage disposal switch (see

Figure 132).

Figure 132

17. Bulk or JIB System: The drain valve closes and the computer displays

SOLUTION

added, alternating with Yes NO. Fill frypot to be cleaned with water and cleaning solution
mix. Referring to maintenance requirement card and Kay Chemical provided instructions “Fryer
Deep Clean Procedure” for McDonald’s deep clean (boil-out) procedure.

18. Bulk or JIB System: Press the (1

yes) button (see Figure 133).


Figure 133

19. Bulk or JIB System: The computer displays

START CLEAN,

alternating with

Yes NO. Press the (1 yes) button (see Figure 134)

to continue and start the cleaning procedure. The vat heats to 195° F (91°
C) for one hour.

Figure 134

The computer displays

DEEP CLEAN with a countdown timer on the display.

After one hour the heater shuts off and the computer displays

CLEAN DONE with an alarm.

20. Bulk or JIB System: Press the (1

yes) button (see Figure 135) to

silence the alarm.

Figure 135

21. Bulk or JIB System: The computer displays

REMOVE SOLUTION

FROM VAT with an alarm. Press the (1 yes) button to silence the
alarm.

Figure 136

DANGER

Allow deep-clean (boil-out) solution to cool to 100°F (38°C) before disposal,
otherwise hot liquid can cause injury.

NOTE: Refer to Kay Chemical provided instructions “Fryer Deep Clean Procedure”

for instructions to remove cleaning solution.