2 review usage mode – Frymaster 14 Series User Manual

Page 57

Advertising
background image

4-39

3. Use the

3and

4 buttons to scroll records; starting at the current day and

going back one week (see Figure 186).


Figure 186


4. Press the

t and

ubuttons (see Figure 187) to scroll between:

Figure 187

FULL VAT CONFIGURATION

a.

DAY (TUE), DATE (07/03/07) – Current day and date.

b.

fIltErEd # day, – Number of times vat filtered and day.

c.

flt bpsd # day, – Number of times filter was bypassed and day.

d.

flt avg day, – Average number of cook cycles per filter and day.

SPLIT VAT CONFIGURATION

a.

DAY (wed), DATE (03/20/07) – Current day and date.

b.

l fIltErEd # DAy – Number of times left vat filtered and day.

c.

L flt bpsd # day, – Number of times left vat filter was bypassed and day.

d.

L flt avg day, – Average number of cook cycles per filter/left vat and day.

e.

R filtered # day, – Number of times right vat filtered and day.

f.

R flt bpsd # day, – Number of times right vat filter was bypassed and day.

g.

R flt avg day, – Average number of cook cycles per filter/right vat and day.

5. Press the (2) button (see Figure 188) to return to

filter stats

prompt.

Figure 188

6. Press the (2) button (see Figure 189) again to quit.

The computer displays

OFF.

Figure 189

4.14.2 REVIEW USAGE MODE

The review usage is used to review historical information for the fryer such as the last date the usage
tracking was reset, the total number of cook cycles per vat, the number of times the cook cycle was
exited prior to completion and the number of hours the vat(s) have been on.

1. Perform steps 1-3 on pages 4-38.

Scroll to

review usage.

2. With

review usage displayed, press the (1 yes) button (see

Figure 190).

Figure 190

The computer displays the date and time of the last reset usage.

Advertising