7-4

Problem

Probable Causes

Corrective Action

M2007 displays

CHANGE FILTER

PAD with yellow and

blue LED’s flashing.

No was chosen on previous

CHANGE

FILTER PAD prompt.

Change filter pad if needed and ensure
the pan is removed from cabinet for at
least TWO minutes. Then press 9 (1
YES) to clear message.

M2007 displays

SERVICE

REQUIRED.

Filter error was not cleared properly.

Call 1-800-551-8633 for assistance.

M2007 displays

BUSY WAIT 30

SECONDS.

Action chosen while MIB is resetting.

Wait until MIB displays “

A”.


7.2.3 Filtration

Problems

Problem

Probable Causes

Corrective Action

A.

Power cord is not plugged in or circuit

breaker is tripped.

A.

Verify that the power cord is fully

plugged in and the circuit breaker is
not tripped.

B.

Pump motor has overheated causing

the thermal overload switch to trip.

B.

If the motor is too hot to touch for

more than a few seconds, the
thermal overload switch has
probably tripped. Allow the motor
to cool at least 45 minutes then press
the Pump Reset Switch.

Filter pump won't start

or pump stops during

filtering.

C.

Blockage in filter pump.

C.

Call 1-800-551-8633 for
assistance.

Drain valve or return

valve stays open.

A.

AIF board has failed.

B. Actuator has failed.

Call 1-800-551-8633 for assistance.

M2007 display shows

chk pan.

A.

Filter pan is not fully set into fryer.

B.

Missing filter pan magnet.

C.

Defective filter pan switch.

A.

Pull filter pan out and fully reinsert

into fryer.

B.

Ensure the filter pan magnet is in

place and replace if missing.

C.

If the filter pan magnet is fully

against the switch and computer
continues to display

chk pan,

switch is possibly defective.

Auto filtration won’t

start.

A.

Check that MIB board is not in manual

mode.

B.

Check to see that the MIB cover is not

damaged and depressing the buttons.

C.

Filter relay has failed.

D.

AIF is set to enabled, blue light

doesn’t light.

A.

Ensure MIB board is in “A”

automatic mode. Press the reset
button.

B.

Remove and replace cover and see

if filtration will start.

C.

Call 1-800-551-8633 for
assistance.

D.

Set AIF in Level 1 to disabled.

Fryer filters after each

cook cycle.

A.

Filter after setting incorrect or software

update issue.

A.

Change or overwrite the filter after

setting by re-entering the filter after
value in level two. Ensure that the
down arrow is pressed after entering
the value to save the setting (see
section 4.13.5 on page 4-36).