Problem probable causes corrective action – Frymaster 14 Series User Manual

Page 75

Advertising
background image

7-3

7.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

M2007 display is in

wrong temperature

scale (Fahrenheit or

Celsius).

Incorrect display option programmed.

Toggle between F° to C° by pressing
and holding

3and4simultaneously

until

code appears. Enter 1658.

The computer displays

OFF. Turn the

computer on to check temperature. If the
desired scale is not displayed, repeat.

M2007 display shows

hot-hi-1.

Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).

Shut the fryer down immediately and
call 1-800-551-8633 for assistance.

M2007 display shows

PROBE FAILURE.

Problem with the temperature
measuring circuitry including the probe.

Shut the fryer down and call 1-800-551-
8633 for assistance.

M2007 display shows

IGNITION

FAILURE.

Open drain valve, failed computer,
failed interface board, open high-limit
thermostat.

Verify that the drain valves are fully
closed. If this does not correct the
problem, call 1-800-551-8633 for
assistance.

M2007 display shows

PROBE FAILURE
with alarm sounding.

Damaged computer wiring harness or
connector.

Call 1-800-551-8633 for assistance.

M2007 display shows

igNITION

FAILURE

with alarm sounding.

Heating indicator is

on, but fryer is not

heating.

Drain valve not fully closed.

Press the reset switch on the front of the
MIB

box, located inside the filter

cabinet. All drain valves should close.
Turn the computer OFF and then ON
again. If the problem continues call 1-
800-551-8633 for assistance.

M2007 display shows

RECOVERY

FAULT and alarm

sounds.

Recovery time exceeded maximum time
limit.

Clear error and silence the alarm by
pressing the 9 button.

M2007 display shows

RECOVERY

FAULT call

service and alarm

sounds.

Recovery time exceeded maximum time
limit for two or more cycles.

Clear error and silence the alarm by
pressing the 9 button. Call 1-800-551-
8633 for assistance. Maximum recovery
time for electric is 1:40.

M2007 display shows

REMOVE

DISCARD.

In non-dedicated mode a product is
dropped that has a different setpoint
than the current vat temperature.

Remove and discard product. Press and
hold the cook button for three seconds
under the display with the error to
remove the error. Reset the setpoint of
the vat before trying to cook product.

Computer locks up.

Computer error.

Call 1-800-551-8633 for assistance.

M2007 displays

CHANGE FILTER

PAD three times and

displays

OFF.

No was chosen on previous

CHANGE

FILTER PAD prompt or yes and no
were pressed consecutively.

Wait 15 minutes until

CHANGE

FILTER PAD is displayed with
flashing lights. Change filter pad if
needed and ensure the pan is removed
from cabinet for at least TWO minutes.
Then press 9 (1

YES) to clear message.

Advertising