33

PNEG-951

decreased too much a popping or fluttering sound will be heard. Also, anytime the high pressure side is adjusted,
the low pressure side needs to be checked. Repeat the test for each fan/heater unit.

DRYER SHUTDOWN

To shut down the dryer,

1. Close the fuel supply valve at the tank or valve along the fuel line.
2. If the burner is operating, let the dryer run out of fuel, and it will shut down automatically due to loss of flame.
3. Close the fuel valve at the dryer, and press the dryer power stop button.
4. Turn off the control power.
5. Turn off the safety disconnect handle on the front of the power box, and turn off the main power to the dryer.

EMERGENCY DRYER SHUTDOWN

In case of emergency push the dryer stop button or the emergency stop button. This will interupt power to the
control panel and the fan, burner and all augers will stop immediately.

Advertising