This message is displayed when the flame detection circuit of your heater is sensing flame when the burner is
supposed to be off. Example, if you shut down the dryer and the heater continues to burn due to a solenoid
stuck in an open state, it will generate this type of error.

Motor Overload x

One of the thermal overloads on either the fan, load, unload or auxiliary motors has opened, indicating an
overcurrent condition. The overloads must be manually reset. The message will distinguish between which fan
overload caused the shutdown. The reference to the number one (1) is telling you that it is fan number 1 which
is the bottom most fan.

Plenum Temp Open x

This error indicates there is a open condition with the plenum temperature sensor located inside the plenum
chamber. This could be a open sensor or the sensor wires could have a open connection.

Plenum Temp Short x

This error indicates there is a shorted condition with the plenum temperature sensor located inside the plenum
chamber. This could be a shorted sensor or the sensor wires could be shorted.

Plenum x Overheat

An over temperature condition has occurred inside the dryer plenum. This control is a 300°F (149°C) limit and
automatically resets itself when cool. The message will distinguish between which plenum caused the shut-
down.

Illegal Flame x