1–6

MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

INTRODUCTION

CHAPTER 1: INTRODUCTION

1.3.4

Physical Specifications

MOUNTING
Vertical: ...............................................................suitable for stand-alone or rack mounting

PACKAGING
Enclosure: ..........................................................rugged high-strength sheet metal
Dimensions:.......................................................1.70 in.

× 17.0 in. × 9.2 in. (H × W × D)

4.32 cm

× 43.2 cm × 22.9 cm (H × W × D)

1.3.5

Approvals and Warranty

APPROVALS
FCC:.......................................................................Emissions meet FCC part 15 class A
NEBS:....................................................................level 3
ETSI:.......................................................................certified for carrier central offices
IEEE: ......................................................................IEEE P1613 environmental standard for electric power

substations

A-rated control power inputs IEEE 1613:2003

Test operation @85% to110% or rated - as per

5.1 and 5.3

AC voltage ranges

IEC60870-2-1

+ / - 10% (AC1)

DC voltage ranges

IEC60870-2-1

+ / - 15% (DC2)

ENVIRONMENTAL TESTS

Relative Humidity Cyclic

EN/IEC 60068-2-30:2005

6-day 93% @ 55deg C

(Variant 2)

Cold Temperature

EN/IEC 60068-2-1: 1993/1990

16 hours -40 deg start up (Ad)

Dry Heat Temperature

EN/IEC 60068-2-2:1994,1974

16 hours at rated upper limit, hot start up (Bd)

Humidity: -34 to 74C, 10-95% NEMA TS2

Humidity: -34 to 74C, 10-95%

Defined in 2.1.5

MECHANICAL TESTS

Sinusoidal Vibration

EN/IEC 60255-21-1 :1996,1988,

10-150hz Response/Endurance @1G (Class 1)

Shock; 2. Bump;

EN/IEC 60255-21-2:1996,1988

Class 2 for shock(30g) and Bump (20g) (Class 2)

Shock

NEMA TS2

10g, x,,y,z (As per 2.2.9)

Vibration Endurance

NEMA TS2

Vibration 5-30Hz 0.015" research+ 1hr(0.5g) dwell

on resonant freq

(As per 2.2.8)

Vibration

MIL-STD -167-1 (variable amplitudes 4-

50Hz)

5-30Hz,0.5g plus resonance frequency dwell

(Type 1 Environmental vibration)

FUNCTIONAL TESTS

Operating Voltage

NEMA TS2 -89-135VAC

Test @max nominal rating (As per 2.1.2)

Operational frequency

NEMA TS2 -57-63Hz

60Hz +/- 3Hz (As per 2.1.3)

SAFETY TESTS

IT -Safety

EN60950-1:2006

UL IT -Safety

UL60950-1

cUL IT -Safety

C22.2 No. 60950-1

Dielectric

IEEE 1613:2003

2000V (2000VAC & 500VAC)

Impulse IEEE

1613:2003

5000V

Standard Name

Standard Number:Date code

Severity levels Tested

Advertising