CHAPTER 17: MISCELLANEOUS COMMANDS
MISCELLANEOUS COMMANDS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
17–5
17.1.3 Configuring Alarm Relays with EnerVista Secure Web Management Software
To customize the alarm relays,
Z
Select the Configuration > Alarms menu item.
Alarm relays (continued)
ML2400(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId
Description
Mode
------------------------------------------
1
S-RING OPEN
NOT ENABLED
2
Cold Start
MOMENTARY
3
Warm Start
NOT ENABLED
4
Link Up
MOMENTARY
5
Link Down
NOT ENABLED
6
Authentication Failure
MOMENTARY
7
RMON Raising Alarm
NOT ENABLED
8
RMON Falling Alarm
MOMENTARY
9
Intruder Alarm
MOMENTARY
10
Link Loss Learn Triggered
MOMENTARY
11
Broadcast Storm Detected
MOMENTARY
12
STP/RSTP Reconfigured
MOMENTARY
ML2400(alarm)##
exit
ML2400#