4 saving configuration, Aving, Onfiguration – GE MULTILINK ML2400 User Manual

Page 92

Advertising
background image

5–20

MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

IP ADDRESSING

CHAPTER 5: IP ADDRESSING

FIGURE 5–4: Displaying configuration for different modules.

Note – multiple modules can be specified on the command line

5.4.4

Saving Configuration

It is advisable to save the configuration before updating the software, as it may be
necessary in certain situations. The

loadconf

command requires a reboot to activate the

new configuration. Without a reboot, the ML2400 used the previous configuration. When
reboot is selected, the user is prompted as follows:

Reboot? ['Y' or 'N']

Select “Y”. The ML2400 will prompt:

Save Current Configuration?

Select “N”.

ML2400#

show config module=snmp,system

[HARDWARE]

type= ML2400

slotB=8 Port TP Module

##########################################################

# System Manager - This area configures System related #

# information. #

##########################################################

[SYSTEM]

***Edit below this line only****

system_name=Main

[email protected]

system_location= Markham, Ontario

boot_mode=manual

system_ip=192.168.1.15

system_subnet=0.0.0.0

system_gateway=192.168.1.11

idle_timeout=10

telnet_access=enable

snmp_access=enable

web_access=enable

--more—
...