GE MULTILINK ML2400 User Manual
Page 275

CHAPTER 17: MISCELLANEOUS COMMANDS
MISCELLANEOUS COMMANDS
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
17–3
Alarm relays (continued)
ML2400(alarm)##
add event=2
Alarm Event(s) Added: 2
ML2400(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId
Description
Mode
------------------------------------------
1
S-RING OPEN
SUSTAINED
2
Cold Start
MOMENTARY
3
Warm Start
MOMENTARY
4
Link Up
MOMENTARY
5
Link Down
MOMENTARY
6
Authentication Failure
MOMENTARY
7
RMON Raising Alarm
MOMENTARY
8
RMON Falling Alarm
MOMENTARY
9
Intruder Alarm
MOMENTARY
10
Link Loss Learn Triggered
MOMENTARY
11
Broadcast Storm Detected
MOMENTARY
12
STP/RSTP Reconfigured
MOMENTARY
ML2400(alarm)##
alarm enable
Alarm system Enabled
ML2400(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: ENABLED
Relay Closure Time Period: 5 Seconds
EventId
Description
Mode
------------------------------------------
1
S-RING OPEN
SUSTAINED
2
Cold Start
MOMENTARY
3
Warm Start
MOMENTARY
4
Link Up
MOMENTARY
5
Link Down
MOMENTARY
6
Authentication Failure
MOMENTARY
7
RMON Raising Alarm
MOMENTARY
8
RMON Falling Alarm
MOMENTARY
9
Intruder Alarm
MOMENTARY
10
Link Loss Learn Triggered
MOMENTARY
11
Broadcast Storm Detected
MOMENTARY
12
STP/RSTP Reconfigured
MOMENTARY
ML2400(alarm)##
alarm disable
Alarm system Disabled
ML2400(alarm)##
del event=1,3,5,7
Alarm Event(s) Deleted: 1, 3, 5, 7
(continued on next page)