Installation Instructions

WALL-MOUNTED INSTALLATION—RECIRCULATING

CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire

with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.

ADVERTISSEMENT

Si la maison n’est pas câblee avec deux fils et un fil
de terre, l’installateur doit installer un fil de terre. Quand
les fils sont en aluminium, il faut prendre soin d’utiliser
des connecteurs aluminium à cuivre avec une pâte
antioxydante approuvée par U.L.

Remove junction box cover and knockout.

Use a conduit connector to secure the conduit to

the junction box.

Connect white leads to branch circuit white lead.
Connect black leads to branch circuit black lead.
Connect green/yellow leads to branch circuit green

lead or bare ground lead.

Secure all connections with wire nuts on each

electrical connector.

Push wires into junction box and replace cover.

Be sure wires are not pinched.

Secure electrical panel cover with original screws.

6

INSTALL DUCT COVERS

Place the decorative duct

covers on top of the hood.

NOTE: The inside piece has
holes on one end intended for
use when the hood is installed
for recirculating purposes.
Be sure the vented end is at
the top, the vent holes will
be visible in this installation.

The inside duct piece must slip
into the folded ends on the outer
section.

Extend the inner duct piece upwards to the ceiling

mounted air deflector.

Secure the duct cover to the air deflector, driving one

screw on each side.

Locate the screw holes on the bottom outside edge

of the hood.

Secure the lower duct cover to the hood by installing

2 screws from the bottom of the hood into the duct
cover.

7

Mounting

screw holes

Vent holes

Install
2 bottom
duct cover
screws

Install 2 screws,

duct cover and

into ceiling

bracket

Advertising