Installation Instructions

ELECTRICAL REQUIREMENTS

230/208 VOLT

ELECTRICAL SUPPLY

Tandem

15 Amp

230/208 volt receptacle configuration

Perpendicular

20 Amp

Large Tandem

30 Amp

• Use ONLY the wiring size recommended for single

outlet branch circuit.

• Proper current protection is the responsibility

of the owner.

A power supply kit must be used to supply power

to the Zoneline unit. The appropriate kit is determined

by the voltage, the means of electrical connection

and the amperage of the branch circuit. See the

POWER CONNECTION CHART on page 13 to select the

appropriate kit.

All wiring, including installation of the receptacle,

must be in accordance with the NEC and local codes,

ordinances and regulations.

Power supply kit

Recommended branch circuit wire sizes*

Nameplate

maximum circuit

AWG Wire

breaker size

size**

15A

14

20A

12

30A

10

AWG – American Wire Gauge
* Single circuit breaker from main box

** Based on copper wire, single insulated conductor at 60° C

NOTE: Use copper conductors only.

FOR 230/208 VOLT CORD

CONNECTIONS ONLY

1. Remove the front panel by taking out the four

front screws, the upper two screws from the top

of the panel and the shipping screws on each side,

if present. (Discard the four side shipping screws,

if present.)

2. Remove the junction box cover and the junction box

and discard.

3. Connect the power cord, with a loop, through

the strain relief.

Strain relief

IMPORTANT:

Power cord must

have a loop.

Remove

junction box

and cover

Side

shipping

screw

Side

shipping

screw