Other features of your zoneline – GE AZ85H12DAC User Manual

Page 8

Advertising
background image

The ventilation control lever is located on the left

side of the Zoneline unit, behind the front case

panel.
To access the ventilation control lever, remove

the front panel by removing the filter, taking out

the four front screws, the upper two screws from

the top of the panel and the shipping screws on

each side, if present. (Discard the four side shipping

screws, if present).
When the lever is in the CLOSE position, only the air

inside the room is circulated and filtered.
When the lever is in the OPEN position, some

outdoor air will be drawn into the room. This

will reduce the heating or cooling efficiency.
To close the vent,

push the vent lever handle

down, pull it forward and lock it up in place.
To open the vent,

push the vent lever handle

down, push it back and lock it up in place.

Energy Tip:

Keep the vent control in the CLOSE

position. The room air will be filtered and circulated.
NOTE: Ventilation openings are not intended to be

the source of make-up air for building ventilation

systems due to the additional heating and cooling

loads generated.

8

Consumer

Support

Troubleshooting

Tips

Care

and

Cleaning

Operating

Instructions

Safety

Instructions

Other features of your Zoneline.

About Heat Pumps

(on some models)

Heat pumps can reduce operating costs by

exchanging heat from the outside air—even

when the outside temperature is below freezing—

and releasing that heat indoors.
To get the best economic benefit from your heat

pump, don’t change the room thermostat setting

very often. Raising the heat setting 2–3 degrees

will cause the Zoneline to use its electric heating

elements in order to reach the new temperature

setting quickly.

There is a three minute minimum compressor run

time at any setting to prevent short cycling.
The indoor fan motor starts before the compressor

and stops after the compressor cycles off.
The electric heating elements use much

more electricity than heat pumps and cost

more to operate.

Ventilation Control

Close

On/Off Switch

The unit on/off switch is located on the front

of the Zoneline.
To turn on the unit,

press the top of the switch in.

To turn off the unit,

press the bottom

of the switch in.
NOTE: The on/off switch does not remove power

from the unit.

ON/OFF

switch

Do Not Operate the Air Conditioner (cool mode) in Freezing Outdoor Conditions

Air conditioners are not designed for use when

freezing outdoor conditions exist. They must not be

used in freezing outdoor conditions.

Open

Vent control (push

lever down and

pull forward or

back to operate)