Top duct

Clamp

Case top

duct adjusting

screws

MAKE UNIT ELECTRICAL

CONNECTIONS

1. Connect the thermostat wires to the unit and set

the dip switches to the appropriate settings.

NOTE: See the Controls–Terminal Connections

and Controls–Dip Switches sections

of this manual and the manual with

the separate thermostat for proper

connections and settings.

2. Make power connections to the unit.
NOTE: See the ELECTRICAL REQUIREMENTS and

DIRECT CONNECT APPLICATIONS

sections,

as appropriate, of this manual for proper

connections.

3. Replace the case front panel by replacing the four

front screws and the two top screws.

6

Installation Instructions

Thermostat

Unit Connections

21

Maximum Wiring

Length for Thermostat

Connection to the Unit

66 ft . for AWG 18

60 ft . for AWG 20

40 ft . for AWG 24

AWG – American Wire Gauge

CONNECT THE TOP DUCT

1. Install the duct onto the air discharge outlet.

2. Secure the top duct to the unit by turning the four

case top duct adjusting screws until they are tight.

Use a field supplied clamp to lock the top duct

to the case.

7

Air

discharge

outlet

Rigid

ductwork

Inside

wall

Flexible or rigid

ductwork