Installation continued operation – Garland G18-BRL User Manual

Page 11

Advertising
background image

Part # 4525958 (05/15/09)

Page 11

INSTALLATION continued

OPERATION

Grid Rack Seasoning Instructions

To insure long life and service, it is imperative that the

cooking surface be carefully broken in or seasoned in the

following manner:

1 . Remove all factory applied protective material by

washing with hot water and a mild detergent or soap

solution . Rinse and dry thoroughly .

2 . Apply a thin coat of olive oil or other high grade salt free

cooking oil to the cooking surface . Wipe away excess .

3 . Turn all valves to a low setting and allow grid racks to

heat slowly for thirty (30) minutes . Allow oil to remain on

cooking surface three (3) to four (4) minutes, then wipe off .

4 . Reset valves to desired operating temperature and apply

a second coat of oil and leave for two (2) or three (3)

minutes after grid rack reaches temperature . Then wipe

off surplus .

Your broiler is now ready to use .

NOTE: Unless products contain sufficient fat, grid racks must

be seasoned before each use . Re-season after thorough

cleaning of the cooking surface .

Lighting Instructions

Models G(18,24,39,36,48)-BRL

1 . One pilot serves two burners and is located between

those burners .

2 . Push red spark buttons several times to ignite pilot

burners .

3 . Ensure pilots are lit by viewing through pilot view hole on

front of unit .

Models GF(18,24,30 .36)-BRL

1 . Push in the valve knob and turn counter-clockwise to the

ignition position .

2 . While holding the knob fully in, depress the ignitor

button and visually confirm that the pilot lights are on .

If the pilot does not light, repeatedly press the ignitor

button until ignition is achieved .

3 . After the pilot is lit, continue to hold the valve knob in for

at least 20 seconds, then release it . If the pilot goes out,

wait five, (5), minutes, then repeat the procedure .

4 . When the pilot is established, push in the valve knob

again and turn it counter-clockwise to the full flame

position, igniting the main burner .

5 . For low flame or simmer, push in the valve knob and turn

it to the low flame position .

6 . To turn the burner off, push in and turn the valve knob to

the circular “OFF” symbol .

Shut down

1 . Turn all gas valves off .

2 . If the unit is to be shut down for an extended period of

time, turn the in-line service valve to the “OFF” position,

(this valve is not factory supplied) .

Two basic types of power ventilations are in use today . One

type is the overhead hood or canopy and the other is the

under shelf exhaust system . The latter offers simplicity of

installation and minimum cleaning expense . Both require

flame-proof filters for easy grease removal .

The ventilator must be connected to a duct of suitable size

with an exhaust blower capable of removing a minimum of

325 CFM’S of air per square foot of broiler surface .