Installation continued – Garland G18-BRL User Manual

Page 8

Advertising
background image

Part # 4525958 (05/15/09)

Page 8

INSTALLATION continued

Gas Supply

A . The type of gas for which the unit is equipped is stamped

on the rating plate . Connect a unit stamped “NAT” only

to natural gas; connect those stamped “PRO” only to

propane gas .

B . If it is a new installation, have gas authorities check meter

size and piping to assure that the unit is supplied with

sufficient amount of gas pressure required to operate the

unit .

C . If it is additional equipment or replacement, have a

qualified gas technician check the gas pressure to make

certain that existing gas facilities (meter, piping, etc .) will

deliver the BTU’S of gas required at the unit with no more

than 1/2” water column pressure drop . When checking

pressure, be certain that other equipment on the same

gas line is on at full rate .

NOTE: When checking pressure, be sure that all other

equipment on the same gas line is on . If the broiler has

been supplied with a regulator it has been preset to

match specifications on the unit’s rating plate . All units

require regulators and should be adjusted accordingly to

manufacturer specifications .

D . The appliance and its individual shut off (supplied by

others) must be disconnected from the gas supply piping

system during any pressure testing of that system at

pressures in excess of 1/2 PSI (3 .45 KPa) .

E . Gas supply connection is made in back lower left hand

corner of unit . A readily accessible approved type of hand

valve should be installed on each supply line . Test for

leaks – Do Not Use An Open Flame .

F . A pressure tap plug is supplied with the units and it

is installed on the manifold . The valve panel must be

removed to use the pressure tap . The gas pressure must

be checked when the unit is installed, to insure that the

unit gas pressure is the same as specified on the rating

plate . If necessary, pressure adjustments must be made at

the pressure regulator .

G . If it is a completely new installation, have gas lines,

meter size piping and piping installed and checked by a

qualified gas technician .

H . Make certain that the new piping, joints, and connections

have been made in a clean manner and have been

purged, so that the piping compound, chips, etc ., will not

clog pilots, valves, and/or controls . Use pipe joint sealant

that is resistant to liquefied petroleum gas .

WARNING: Check gas connections for leaks . Use a soap

solution or similar means . Do Not Use An Open Flame!

Gas Connections

All broilers have a rear gas 3/4” NPT or 3/4”-14NPT

connections . CE models have 3/4”-14 BSPT thread adapter .

NOTE: Adequate clearance must be provided for servicing

and proper operation .

Counter Line Installations
Location

Unpack units carefully and provide the necessary space

on counter or back bar . All units must be installed in non-

combustible locations .

A . Location of the unit should be in an area where

make-up air is available to support proper combustion .

Make-up air should be supplied in such a manner as to

pass through the front of the unit . Do not obstruct front-

air flow .

B . In accordance with standard gas appliance operation,

the unit should be located under a ventilation hood of

applicable size and capacity . See ventilation instructions .

Sanitary Counter Top Seal

When the broiler is installed on a counter top, the National

Sanitation Foundation, (NSF), recommends that it be

sealed in accordance with NSF standards per the following

instructions:

1 . Unit should be located on a non-combustible, level

counter top surface .

2 . Thoroughly clean the bottom perimeter of the broiler and

the counter top around the bottom of the broiler .

3 . Apply a generous bead of silicone sealant around the

entire outside perimeter of the broiler bottom .

4 . The broiler can be secured to the counter top by inserting

the 3/8-inch diameter crating bolts through the counter

from the bottom, (via predrilled 1/2” diameter holes), and

threading them into the nut inserts in the bottom of the

unit .

5 . Smooth the silicone sealant with a finger or tool to

provide a cover seal .

Advertising