GE FGB-M05 User Manual

Page 11

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 10

Gravimetric

Blender

2.7.2.2 Method Percentage

The different component are defi ned as follows:

Regrind

:

Percentage of the batch weight

Natural

:

Percentage of the batch weight

Additive

:

Percentage of the batch weight

Total sum must be 100%.

Example

Batchweight

2000

gr.

Regrind

20.0%

Natural

1

60.0%

Natural

2

15.0%

Additive

5.0%

Regrind

: 20.0%

of

2000.0

400.0

Natural

1

: 60.0%

of

2000.0

1200.0

Natural

2

: 15.0%

of

2000.0

300.0

Additive

: 5.0%

of

2000.0

100.0

TOTAL 2000.0

2.7.3 Adding extra materials

The

defi ned amount of the component defi ned in the recipes can be changed external

using some special parameters. The controller has two methods: ‘Additive to regrind’ and

‘Regrind Control’.

IMPORTANT

Addition of extra material using ‘Additive to regrind’ and ‘Regrind Control’ is only

possible when a ‘standard’ recipe is used.

Advertising