GE FGB-M05 User Manual

Page 7

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 6

Gravimetric

Blender

Pause

When the pause-command is given for a temporary stop the blender will stop after the

cycle is complete.

Stop

requested

The blender is operating but has received a stop-command. The stop-command will be

executed at the end of a batch-cycle. This status will be replaced automatically with ‘standby’

if nothing is done. If a start-command is given during the status ‘stop requested’ the status

will

be

‘operate’ again.

Error

The controller has detected an error and therefore the system will stop. In a sub-menu at

the operator-interface the error will be displayed. The error situation can be recovered using

the <ENTER> command. The error must be solved then.

2.3

Machine-mode

The controller can be in two modes: Automatic and Manual. The operator can change the

mode using the menu item ‘controller’. This changing of mode is only possible while the

blender has status ‘standby’.

If a controller is in Automatic-mode, the recipe will be executed without the need of

an operator. This mode is used for production purposes and is only dependent on the

settings

‘production-mode’.

In automatic mode the keys mentioned below mean:

F5

Start-command

(start-key)

F6

Stop-command

(stop-key)

F7

Pause-command

F8

Continue-command

(clear

pause)

After a start-command in Manual-mode one batch will be executed. After this the machine-

status will be ‘standby’ again. The weighbin and mixbin-valve can be controlled manually.

In manual mode the keys mentioned below meaning:

F5

Step-command (One component of a batch)

F6

Reset-command (Back to the fi rst component of a batch)

F7

Empty

weighbin

F8

Empty

mixbin

Advertising