Gravimetric

Blender

Step: Use the arrow-keys

<↓> to select a component and press <ENTER>.

Use the arrow-key

<?> to select Quantity. Enter the quantity and press <ENTER>.

Use the arrow-key

<→> to select Alarmtype and press <ENTER>.

Alarm

Ignore

Ignore

Warning

Error

Step: Select an alarm type by using the arrow-keys and press <ENTER>.

It is not necessary to enter a speed (g/s) because the terminal already has entered

standard values and the GraviMaster calculates new speeds and updates the recipe.

Step: Press the arrow-key

<ο> to select the next hopper number.

Depending on the model, it is possible to use upto 12 hoppers.

The terminal has a keyboard but the keyboard doesn’t contain characters. Therefore it is

possible to connect a standard AT keyboard to the terminal. This keyboard must connect to

a connector which is placed on the PCB in the terminal. When using a AT keyboard, than:

Switch power off the terminal

Disconnect the internal keypath from the PC board

Connect the AT keyboard on the PC board

Switch on the terminal


Now you can use the AT-keyboard. When you are ready, than connect the terminal-keyboard

again. This has to be done when the terminal is switched off.


3.2.3 Change current recipe

When an operator wishes to produce a new product a change of the current recipe must be

done. To change the current recipe select menu (F1) ‘controller / select recipe’. The terminal

now shows a list with all recipes. The recipe which is marked with an

<↓> is the actual

recipe, this recipe is also loaded in the controller.

IMPORTANT

When a new recipe is selected be sure that all hoppers are fi lled with material. The controller
calculates new dispense-rates by a fast algorithm in the fi rst 5 batches.