GraviMaster-FGB-M05 (S)

Page 28

Gravimetric

Blender

Step: Use the arrow-keys

<↓> to select a component and press <ENTER>.

Use the arrow-key

<?> to select Quantity. Enter the quantity and press <ENTER>.

Use the arrow-key

<→> to select Alarmtype and press <ENTER>.

Alarm

Ignore

Ignore

Warning

Error

Step: Select an alarm type by using the arrow-keys and press <ENTER>.

It is not necessary to enter a speed (g/s) because the terminal already has entered

standard values and the GraviMaster calculates new speeds and updates the recipe.

Step: Press the arrow-key

<ο> to select the next hopper number.

Depending on the model, it is possible to use upto 12 hoppers.

The terminal has a keyboard but the keyboard doesn’t contain characters. Therefore it is

possible to connect a standard AT keyboard to the terminal. This keyboard must connect to

a connector which is placed on the PCB in the terminal. When using a AT keyboard, than:

•

Switch power off the terminal

•

Disconnect the internal keypath from the PC board

•

Connect the AT keyboard on the PC board

•

Switch on the terminal


Now you can use the AT-keyboard. When you are ready, than connect the terminal-keyboard

again. This has to be done when the terminal is switched off.


3.2.3 Change current recipe

When an operator wishes to produce a new product a change of the current recipe must be

done. To change the current recipe select menu (F1) ‘controller / select recipe’. The terminal

now shows a list with all recipes. The recipe which is marked with an

<↓> is the actual

recipe, this recipe is also loaded in the controller.

IMPORTANT

When a new recipe is selected be sure that all hoppers are fi lled with material. The controller
calculates new dispense-rates by a fast algorithm in the fi rst 5 batches.