GE FGB-M05 User Manual

Page 9

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 8

Gravimetric

Blender

2.6 Dispense

modes

The blender has two ways of dispensing: gravimetric and volumetric. One mode can be

selected or a combination of both. This can be defi ned choosing menu (F1) ‘controller /

public

parameters’.

Gravimetric

All component of the batch are dispensed and measured separately. Gravimetric is more

accurate than volumetric, but takes more production time, ie., lower output.

Volumetric

All components of the batch are dispensed at the same time using the dispense time of each

component (calculated by the system). The components are dumped directly in the mixer

chamber. No measurement is done in this mode. Therefore this method is less accurate, but

the production time is faster, ie., maximum output

Combination

When combination is defi ned, one gravimetric will be followed by a defi ned number of

volumetric

dispenses.

This

is

defi ned by the parameter combinationRatio. This parameter can

only be defi ned if ‘combination’ is chosen. This mode has the best of gravimetric and

volumetric.

Use: normally the defi ned combination will be done (ex. 1:3). However, if the mixer chamber

is full, the process will automatically do a gravimetric dispense instead of a (possible)

volumetric

one.

2.7

Batch handling

2.7.1 Production control

If a start command is given the controller will check if the blender actually can start. If a

hopper has a low-indication (optional) the controller will alarm.

Also the parameters are checked. These can be in confl ict with the recipe to be executed.

The following items will be checked (if applicable):

* Empty Regrind control

- The controlled hopper must contain regrind (according to recipe)

* Stock silo control (optional)

- Controlled hopper must contain regrind (according to recipe)

*

Additive

to

regrind

- Controlled hopper must contain additive (according to recipe)

The blender will not start unless all conditions are met. A message will be sent to the user interface.