GE FGB-M05 User Manual

Page 8

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 7

Gravimetric

Blender

2.4 Production-modes

The production-mode of the blender indicates how the production will stop in automatic-

mode. This parameter can be changed using the menu (F1) ‘controller / public parameters’.

The production-mode has three options:

Continue

The blender will not stop automatically after the start-command. The blender will continue

the production, unless the blender runs out of material or an error occurs.

Weight->Alarm
If

‘Weight->Alarm’ has been chosen, a requested weight has to be given. After a start the

requested weight will be compared with ‘produced-weight’. If both are the same or the

‘produced-weight’ higher, the controller

will send an alarm to the operator-interface. The

production will continue.

The alarm can be recovered setting the ‘production-weight’ to zero (0). This command is part

of the option-menu (F2) of the status screen.

Weight->Error

When using the option ‘Weight->Error’ a weight has to be given. After a start the requested

weight will be

compared with ‘production-weight’. If both are the same or the

‘production-weight’ higher, the controller will send an error to the operator-interface. The

production will not continue in this case.

2.5

Mixer-mode

When all components are dispensed, the contents of the weighbin will be emptied. The

mixer in the mixing chamber, which contains the dispensed components, can be put in

different modes. Choose the menu (F1) ‘controller/public parameters’.

Normal

The mixer is off during production. If the components are dumped from the weighbin into the

mixer chamber the mixer will be on for a predefi ned number of seconds, defi ned by

‘mixerOnTime’. This parameter can only be changed if this option is chosen.

Pulsing

The mixer will pulse during production. Both on- and off-time ca be defi ned using the

parameters mixerPulseOnTime (time on) and mixerPulseOffTime (time off). These

parameters can only be changed if this option is chosen.

Off

The mixer is always off.

On

The mixer is always on, when the machine status is active.