GE FGB-M05 User Manual

Page 36

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 35

Gravimetric

Blender

PROTECTED PARAMETERS

Parameter Description

Init

BatchWeight

Total weight of one batch. This value is copied into 0,5 [kg]

every recipe when it is created.

DispenseTry

Maximum number of tries per component to reach 4

maximum

accuracy

DispenseAccuracy

Minimum accuracy for each component.

25 [%]

DispenseRate

Maximum deviation when a re-calculation of the

30 [%]

CorrectionBand

dispense-speed is done

SiloPresent Indicates

the

‘Stock-Silo’ regrind control process

No

is

activated.

MaximumTare

Maximum absolute deviation from the zeropoint

40 [g]

Variation

of the weighbin.

SiloHighCount

Number of batches with the highness activated

100

before the controller initiates an alarm.

SiloLowCount

Number of batches with the lowsensor not activated 100

before the controller initiates an alarm.

EmptyRegrind Indicates

the

‘Empty Regrind’ regrind control

No

process is activated.

EmptyRegrindHopper Indicates the hopper which is used in the empty

Hopper 1

regrind

process

EmptyRegrindCycles Number of batches empty regrind waits before

1

increasing regrind (startprocess)

Dispense inc/dec

Maximum percentage for the regrind control

10 [%]

processes

Dispense

Number of steps in whitch the maximum must

10

VariationCycles be

reached.

LoadcellGain Amplifi cation-factor for the loadcell signal

16

LoadcellOverload

Maximum weight in the weighbin. The controller

800 [g]

initiates an error on this point.

LoadcellSettleTime

Time between the dispense of the last component

1 [s]

and reading the weigbin-signal.

(to eliminate vibrations).

LoadcellWeight

To read a correct weight 8 samples must fi t to this

10 [g]

BandWidth absolute

band.

FGB-Name/Nr.

Name of the controller; This name is used in the

user-interface of the terminal.