GE FGB-M05 User Manual

Page 31

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 30

Gravimetric

Blender

OPERATING AUTO[ ] [ ] [ ]
STATUS:[0] FGB#00: (No name) STATUS OPERATING MODE: AUTOMATIC

PRODUCTION

STATUS]

Production mode :

CONTINUE

Dispense mode: GRAVIMETRIC

Name:

PIR-HOUSING

Mix mode

:

PULSE

Recipe

CRATES

YELLOW

[current]

[previous]

[total]


H# Type

Recipe Requested

Dispensed Recipe

Dispensed Recipe Dispensed

1 REG

[ 20.0] 400.0

20.0

400.0

20.0 1600

2 NAT

[ 1.0] 1523.8

1.0

1523.8

1.0 6095

3 ADD

[ 5.0] 76.2

5.0

76.2

5.0 305

4
5
6
7
8
9
10
11
12

totals
[ACCEPT] [UNDO CHANGES] 0.1 2000.0 8000
Produced weight: 82000
F1Menu

F2Option

F3 F4Node F5Start

F6Stop

F7Pauze

F8Cont.

During production it is possible to change the recipe without a change of the current recipe.

The recipe can be changed in the production-screen by selecting a fi eld (arrow-keys). Next

enter a new value and press <ENTER> to confi rm. Now the recipe is changed but the

controller uses the new values at the start of a new batch.

3.3.2 Material usage screen

The material usage screen menu (F1) ‘production / material usage’ displays the total

quantity of material witch is used ordered by hopper number. The quantities which are stored

doesn’t depend on the current recipe. The material usage screen is erased from memory by

one of the following actions:

* Command given by the operator

* After a operator prints the screen.

This is possible by using option-key (F2) and selecting the option you require and pressing

<ENTER>.

Other values witch are stored in the material usage screen are: date of the last erase-action,

number of batch-cycles and production speed (kg/hour).

Advertising