GE FGB-M05 User Manual

Page 34

Advertising
background image

Rev. May 2001

GraviMaster-FGB-M05 (S)

Page 33

Gravimetric

Blender

PUBLIC

PARAMETERS

Parameter Description

Init

AlarmReport

Indicates if alarm-reports must be printed.

No

*)

ProductionReport

Indicates if production-reports must be printed.

No

*)

If so the parameter interval-time must be given also.

Interval

Pauze (time) before printing the next production-report. 01:00.00

BatchReport

Indicates if batch-reports must be printed.

No

*)

ProductionMode

Actual production-mode. There are three possible

CONTINUE

modes; CONTINUE, WEIGHT and ALARM_

WEIGHT. If the mode WEIGHT os ALARM_

WEIGHT has been selected the parameter production

Weight must also be given.

ProductionWeight

The FGB stops his production when the production

100 [Kg]

Weight is reached. (productionMode must be

WEIGHT

or

ALARM_WEIGHT).

DispenseMode

Actual dispense-mode. There are three possible

GRAVIMETRIC

modes; GRAVIMETRIC, VOLUMETRIC and

COMBINATION. If the mode COMBINATION is

chosen the parameter combinationRatio must be given.

CombinationRatio

Relation between the volumetric and gravimetric

3

dispenses. (one gravimetric dispense and x

volumetric

dispenses).

MixMode

Actual mixermode. There are four possible modes;

PULSE

ON, OFF, NORMAL and PULSE. In normal-mode

the parameter mixerOnTime must be given. In the

mode pulse the parameters mixerPulseOnTime and

mixerPulseOffTime must be given.

MixerOnTime

Time the mixer is activated after the material is

10 [s]

dumped out of the weighbin.

MixerPulseOnTime

Time the mixer is activated in pulse-mode.

5 [s]

MixerPulseOffTime

Time the mixer is not activated in pulse-mode.

15 [s]

AdditiveToRegrind

Percentage additive to regrind which must be added. 0 [%]

Percentage 1/2
AdditiveToRegrind

Hoppernumber in which the additive is.

Hopper 5

Hopper 1/2

WeighbinDumpTime

Time the weighbinvalve is activated (dumping of

4 [s] 0,5 kg unit

material into the mixerchamber).

6 [s] 1,2,5 and

25 kg unit

LevelControlWaitTime

Time between the full signal of the mixerchamber

8 [s]

sensor and opening the mixerchamber-valve.

LevelControlDumpTime Time between the free signal of the mixerchamber

sensor and closing the mixerchamber-valve.

1 [s]

*)

No = [ ], Yes = [X]

Advertising