Gravimetric

Blender

ALARMS

Alarm-message

Description

Action to cancel alarm

Press enter

Alarm already cancelled

Press enter

Operator must confi rm

No control voltage

No 24V control voltage present

Turn on the main-switch

or check fuses

Covers open

Security cover not present or mixerchamber

Place security-cover /

removed

mixer-chamber

Production weight

producedWeight equals produktionweight

Reset the

reached

producedWeight

No weighbin or

Zero weight of the weighbin is greater then

Loadcell must be

calibrate

‘maximumTareVariation’

calibrated or a tare

procedure must be done.

Parameters corrupted

The controller can’t read his parameters

Check the parameters

*)

correctly. All parameters will be fi lled with

standard

values.

Data corrupted

The controller can’t read the productiondata

Confi rm

*)

(production-screen). The data will be cleared.

Hopper low

The hoppersensor (optional) indicates that a

Fill hopper with material

hopper runs out of material.

Hopper empty

No material is dispensed so the controller

Fill hopper with material and

indicates that a hopper must be empty.

press the start-button.

***)

Loadcell not calibrated The controller can’t read the loadcell

Calibrate the weighbin

parameters

correctly.

Loadcell overload

Weight of the weighbin is greater than the

Remove material out of

loadcellOverload parameter.

the weigbin.

Check in recipe the

Loadcell not stable

Weightsignal from the loadcell doesn’t fi t

Press enter

*) **)

the

band.

Loadcell need

Controller needs more samples to generate a

Press enter

*)

more samples

stable weight.

Loadcell boundary error To much weight-samples doesn’t fi t the band. Press enter

*)

Silo high

Silo supply hopper is full for several batches. Counter will

(High sensor is activated)

automaticaly cleared.

Regrind process par

Given hoppernumbers doesn’t contain regrind Check the regrind

confl ict

or percentage

control parameters

Additive regrind par

Given hoppernumber doesn’t contain additive Check the

confl ict

AdditiveToRegind

parameters