8. remote 14 receptacle – Miller Electric SYNCROWAVE 250 TM-353E User Manual

Page 14

Advertising
background image

TM-353 Page 10

Syncrowave 250

3-8.

Remote 14 Receptacle

Socket*

Socket Information

A

24 volts ac.

B

Contact closure to A completes 24 volts ac contactor control
circuit.

C

Command reference; 0 to +10 volts dc output to remote control.

A

J

B

K

I

D

Remote control circuit common.

C

L

N

H

D

M

G

F

A

E

0 to +10 volts dc input command signal from remote control.

E

F

ST-154 795-C

K

Chassis common.

*The remaining sockets are not used.

3-9.

115 Volts AC Duplex Receptacle And Shielding Gas Connections

Ref. ST-154 795-C / Ref. ST-157 858

Y

Turn Off power before
connecting to receptacle.

1

115 V AC Receptacle

Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 7-2).

2

Gas Valve In Fitting

3

Gas Valve Out Fitting

Fittings have 5/8-18 right-hand
threads

4

Cylinder Valve

Open valve slightly so gas flow
blows dirt from valve. Close valve.

5

Regulator/Flow Gauge

6

Flow Adjust

Typical flow rate is 20 cfh (cubic feet
per hour) (9.4 L/min)

7

High Frequency Control (see
Section 4-1)

4

5

6

1

7

3

2