8. meter calibration – Miller Electric SYNCROWAVE 250 TM-353E User Manual
Page 39
Advertising
TM-353 Page 35
Syncrowave 250
6-8.
Meter Calibration
SB-130 690-D / ST-800 344-A
Be sure plugs are secure before
calibrating meter.
1
Control Board PC1
2
Voltmeter V1
3
Ammeter A1
Top View
R19
Amperes
No calibration available for ammeter
offset, or for voltmeter V1.
1
2
3
Adjust R19 for amperage gain to
match external calibrated meter
using load bank set at desired
load.