TM-353 Page 38

Syncrowave 250

7-3.

Fuses F1 And F2

1

Fuse F1 (See Parts List For
Rating)

Fuse F1 (between leads 50 and
150) protects wiring harness from
shorted SR2. If F1 opens, you may
experience problems with arc start-
ing and arc performance in the DC
TIG mode.

2

Fuse F2 (See Parts List For
Rating)

Fuse F2 (between leads 22 and
149) protects wiring harness from
shorted SR3. If F2 opens, you may
experience problems with arc con-
trol, and no high frequency in start
high frequency.

Tools Needed:

1

2

3/8 in

7-4.

Adjusting Spark Gaps

Ref. ST-154 795-C / Ref. S-0043

Tools Needed:

1

4

3

4

3

2

Y

Turn Off power before
adjusting spark gaps.

Open access door.

1

Tungsten End Of Point

Replace point if tungsten end dis-
appears; do not clean or dress
tungsten.

2

Spark Gap

Normal spark gap is 0.008 in (0.203
mm).

If adjustment is needed, proceed as
follows:

3

Adjustment Screws

Loosen screws. Place gauge of
proper thickness in spark gap.

4

Pressure Point

Apply slight pressure at point until
gauge is held firmly in gap. Tighten
screws to 12 in/lbs torque (overtigh-
tening will deform plastic base). Ad-
just other gap.

Close access door.

Advertising