TM-353 Page 32

Syncrowave 250

Receptacle

Value

Pin

RC55

1

Circuit common

2

+1.65 volts dc per 100 amperes of weld output with respect to pin 1

3

–15 volts dc output

4

0 to +4 volts dc input from min. to max. of Arc Control R2 with Arc Control switch S6 On

5

10 volts ac input for synchronization

6

+5.8 volts dc output

7

–15 volts dc input from Max. Penetration setting of AC Balance control R3 to +5.8 volts dc input at
Max. Cleaning setting of R3

8

0 to 80 volts dc voltage feedback signal (rectified arc voltage) with respect to pin 9

9

0 to 80 volts dc voltage feedback signal (rectified arc voltage) with respect to pin 8

10

0 to +4 volts dc input from min. to max. of Arc Control R2 with Arc Control switch S6 Off