3-11. Placing Jumper Links And Connecting Input Power

ST-117 263-K

Check input voltage available at
site.

1

Jumper Link Label

Check label inside your unit–
only one label is on unit.

Y

Only make connections for
the voltages shown on the la-
bel inside your unit. Do not
make connections for any
other voltages. If jumper link
label is missing from inside
unit, check rating label (see
Section 3-4) for allowable in-
put voltages.

2

Jumper Links

Move jumper links to match input
voltage.

3

Input And Grounding
Conductors

Select size and length using
Section 3-10.

4

Line Disconnect Device

Select type and size of overcurrent
protection using Section 3-10.

Reinstall side panel.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

3/8 in

3/8, 1/2, 7/16 in

Tools Needed:

230 VOLTS

L

L

460 VOLTS

L

L

S-010 587-B

575 VOLTS

L

L

230 VOLTS

460 VOLTS

200 VOLTS

L

L

L

L

L

L

S-083 566-C

2

L1 (U)

L2 (V)

GND/PE
Earth Ground

4

3

220 VOLTS

L

L

380 VOLTS

L

L

S-131 783-A

415 VOLTS

L

L

Connect GND/PE
Conductor First

Connect GND/PE
Conductor First

S-047 672-A

260 VOLTS

L

L

380 VOLTS

L

L

520 VOLTS

L

L