Miller Electric SYNCROWAVE 250 TM-353E User Manual

Page 25

Advertising
background image

TM-353 Page 21

Syncrowave 250

15 115 Volts AC Duplex Recep-

tacle RC2

Provides connection point for auxil-
iary equipment.

16 Postflow Timer TD1

Controls shielding gas and coolant
postflow time.

17 Gas Valve GS1

Provides shielding gas during the
weld cycle.

18 Preflow Timer TD3, Control

R12, And Switch S9

R12 selects time shielding gas
flows before arc starts. S9 is an in-
tegral part of R12 so that when R12
is turned past zero (0), TD3 is off.

19 Spot Timer TD2, Switch S8,

And Control R10

R10 selects time output is available
when spot welding. S8 selects Off
or spot welding with remote contac-
tor control.

20 High Frequency Transformer

T2

Steps up input voltage and charges
capacitor C4.

21 Spark Gaps G And High Fre-

quency Coupling Coil T3

G provides path for C4 to discharge
into T3. T3 supplies high-frequency
to welding circuit.

22 High Frequency Intensity

Control R13

Changes amount of HF energy
used to start and maintain the arc.

23 Main Rectifier SR1

Changes the ac output from T1 to
full-wave rectified dc.

24 Background Power Source

Provides reduced weld output rip-
ple at low weld output levels.

25 Stabilizer Z1

Smooths dc welding current.

26 Hall Device HD1

Provides current feedback signal to
PC1 through line filter FL1.

27 Line Filter FL1

Filters current feedback signal.

28 Output Selector Switch S4

Provides either AC or DC and out-
put polarity.

29 Integrated Rectifier SR2

Provides dc voltage feedback to
PC1.

30 Electrode And Work Weld

Output Terminals

Provide weld output.

Hall Device

HD1

Optional

AC Or DC Control

External Circuits

Weld Current Circuit

Stabilizer

Z1

Work Weld

Electrode

Output

Terminal

Weld Output

Terminal

High

Frequency

Coupling

Coil T3

Current Feedback

Voltage Feedback

High

Frequency

Intensity

Control R13

Spark Gaps G

High

Frequency

Transformer

T2

1

φ

Power

25

26

28

30

21

30

22

21

20

Capacitor

C4

Integrated

Rectifier

SR2

29

Line

Filter

FL1

Preflow

Timer

TD3

Preflow Time

Control

R12

Switch

S9

Spot

Timer

TD2

Spot Time

Control

R10

Voltmeter

V1

18

18

19

19

11

27

115 VAC

Spot Time

19

Switch

S8

Output

Selector

Switch

S4

Voltage Feedback

Advertising