SECTION 3 − INTRODUCTION

3-1. Specifications

Rated Output at

Voltage

Range in

Amperage

Range in

Max. Open-

Circuit

RMS Amps Input at Rated

Load Output, 60 Hz 3-Phase

at NEMA Load Voltages and

Class I Rating

Rated Output at

60% Duty Cycle

Range in

CV Mode

Range in

CC Mode

Circuit

Voltage

230 V

460 V

KVA**

KW**

300 A at 32 VDC, 3-Phase

10−35 V

5−400 A

90 VDC

30.5

(0.21*)

18.9

(0.10*)

12.2

(0.09*)

11.6

(0.04*)

225 A at 29 VDC, 1-Phase

47.4

(0.34*)

24.5

(0.14*)

11.3

(0.09*)

7.6

(0.04*)

*While idling
** Information based on 230 V, 3-phase input line.

3-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, output stops, a

Help message is displayed (see

Section 7-3), and cooling fan runs.

Wait fifteen minutes for unit to cool.

Reduce amperage or voltage, or

duty cycle before welding.
NOTICE − Exceeding duty cycle

can damage unit and void warranty.

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

sduty1 5/95 / SA-207 877

6 Minutes Welding

4 Minutes Resting

60% Duty Cycle