OM-188 304 Page 15

4-3. Remote 14 Receptacle Information

Socket*

Socket Information

A

J

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

A

J

B

K

I

C L N

H

24 VOLTS AC

B

Contact closure to A completes 24 volts ac

contactor control circuit.

C L N

H

D M

G

F

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

E

F

115 VOLTS AC

J

Contact closure to I completes 115 volts ac

contactor control circuit.

C

Output to remote control; +10 volts dc.

REMOTE

OUTPUT

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from

remote control.

A/V

F

Current feedback; +1 volt dc per 100 amperes.

A/V

AMPERAGE

VOLTAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

tacle volts.

GND

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

4-4. Optional 115 Volt AC Duplex Receptacle And Circuit Breakers

ST-801 245-A

1

115 V 10 A AC Receptacle

Power is shared between duplex

receptacle and Remote 14 recep-

tacle (see Section 4-3).
2

Circuit Breaker CB1

CB1 protects duplex receptacle

and 115 volt ac portion of Remote

14 receptacle from overload.
3

Circuit Breaker CB2

CB2 protects 24 volt ac portion of

Remote 14 receptacle from

overload.
Press button to reset breaker.

2

3

1

Advertising