OM-188 304 Page 31

Program 11 −− .045 Metal Core −− Recommended Gases: Argon/CO

2

Gas: Argon/CO

2

mixes up to 20% CO

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

100

0

310

45

50

2.30

529

145

10

330

61

65

2.45

529

190

20

354

70

90

2.55

529

235

30

365

78

110

2.65

529

280

40

370

89

130

2.75

529

325

50

376

100

150

2.85

529

370

60

381

111

165

3.00

529

415

70

385

122

180

3.15

529

460

80

390

138

190

3.25

529

505

90

395

155

200

3.35

529

550

100

400

175

205

3.45

529

Program 12 −− .052 Metal Core −− Recommended Gases: Argon/CO

2

Gas: Argon/CO

2

mixes up to 20% CO

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

60

0

360

36

40

2.00

529

99

10

365

70

50

2.10

529

138

20

370

94

73

2.20

529

177

30

374

116

94

2.35

529

216

40

379

133

112

2.50

529

255

50

384

147

129

2.65

529

294

60

387

160

144

2.85

529

333

70

390

174

159

3.00

529

372

80

393

186

174

3.15

529

411

90

396

199

189

3.35

529

450

100

400

210