OM-188 304 Page 33

7-3. Voltmeter/Ammeter Help Displays

.

All directions are in reference to the front
of the unit. All circuitry referred to is lo-

cated inside the unit.

1

Help 0 Display

Indicates a shorted thermistor RT2 on the left

side of the unit. If this display is shown, con-

tact a Factory Authorized Service Agent.
2

Help 1 Display

Indicates a malfunction in the primary power

circuit. If this display is shown, contact a Fac-

tory Authorized Service Agent.
3

Help 2 Display

Indicates a malfunction in the thermal

protection circuitry located on the left side of

the unit. If this display is shown, contact a

Factory Authorized Service Agent.
4

Help 3 Display

Indicates the left side of the unit has over-

heated. The unit has shut down to allow the

fan to cool it (see Section 3-2). Operation will

continue when the unit has cooled.

5

Help 4 Display

Indicates a malfunction in the thermal

protection circuitry located on the right side

of the unit. If this display is shown, contact a

Factory Authorized Service Agent.

6

Help 5 Display

Indicates the right side of the unit has over-

heated. The unit has shut down to allow the

fan to cool it (see Section 3-2). Operation will

continue when the unit has cooled.

7

Help 6 Display

Indicates that the input voltage is too low and

the unit has automatically shut down. Opera-

tion will continue when the voltage is within

the acceptable lower range limit (15% below

the applicable input voltage). If this display is

shown, have an electrician check the input

voltage.
8

Help 7 Display

Indicates that the input voltage is too high

and the unit has automatically shut down.

Operation will continue when the voltage is

within the acceptable upper range limit (15%

above the applicable input voltage). If this

display is shown, have an electrician check

the input voltage. Help 7 can also indicate a

bus voltage imbalance.
9

Help 8 Display

Indicates a malfunction in the secondary

power circuit of the unit. If this display is

shown, contact a Factory Authorized Ser-

vice Agent.
10 Help 9 Display
Indicates a shorted thermistor RT1 on the

right side of the unit. If this display is shown,

contact a Factory Authorized Service Agent.

1

A

V

2

A

V

3

A

V

HE.L P−0

HE.L P−1

HE.L P−2

4

A

V

HE.L P−3

5

A

V

HE.L P−4

6

A

V

7

A

V

8

A

V

HE.L P−5

HE.L P−6

HE.L P−7

9

A

V

HE.L P−8

10

A

V

HE.L P−9