Miller Electric 460Volt User Manual

Page 32

Advertising
background image

OM-188 304 Page 28

Program 2 −− .045 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO

2

Gas: Argon/CO

2

mixes up to 10% CO

2

;

Argon/O

2

mixes up to 5% O

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

80

0

323

48

56

2.20

498

127

10

342

61

91

2.28

529

174

20

370

84

108

2.38

529

221

30

388

95

134

2.53

529

268

40

390

108

155

2.65

529

315

50

400

119

175

2.73

529

362

60

400

139

183

2.83

529

409

70

400

152

200

2.86

529

456

80

400

178

215

2.93

529

503

90

400

219

230

2.99

529

550

100

400

277

250

3.10

529

Program 3 −− .035 309L Stainless Steel −− Recommended Gases: 98% Argon/2% CO

2

Alternative Gases: Argon/CO

2

mixes up to 10% CO

2

;

Argon/O

2

mixes up to 5% O

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

100

0

257

26

57

1.62

400

168

10

266

44

82

1.75

430

236

20

282

70

91

1.85

456

304

30

298

84

106

1.97

482

372

40

315

89

123

2.02

503

440

50

328

95

135

2.08

520

508

60

349

107

144

2.19

529

576

70

362

112

171

2.25

529

644

80

376

118

180

2.30

529

712

90

395

122

183

2.33

529

780

100

400

123

190

2.43

529

Program 4 −− .045 309L Stainless Steel −− Recommended Gases: Argon/CO

2

Gas: Argon/CO

2

mixes up to 10% CO

2

;

Argon/O

2

mixes up to 5% O

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

95

0

295

35

90

1.80

448

147

10

318

54

105

2.00

481

198

20

351

75

125

2.00

508

250

30

359

97

143

2.20

529

301

40

379

100

160

2.40

529

353

50

390

109

175

2.50

529

404

60

400

117

185

2.50

529

456

70

400

133

200

2.65

529

507

80

400

149

220

2.70

529

559

90

400

166

240

2.83

529

610

100

400

175

260

2.80

529

Advertising