Miller Electric 460Volt User Manual

Page 18

Advertising
background image

OM-188 304 Page 14

4-2. Weld Output Receptacles And Selecting Cable Sizes

!

ARC WELDING can cause Electromagnetic Interference.

To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed

and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving

the welding machine, using shielded cables, using line filters, or shielding the work area.

Weld Output

Terminals

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

Not Exceeding***

!

Turn off power before

connecting to weld out-

put terminals.

!

Do not use worn, dam-

aged, undersized, or

poorly spliced cables.

100 ft (30 m) or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 4/0 (120)

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 2/0

(2x70)

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

+

Output Receptacles

400

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120) 2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

2 ea. 4/0

(2x120)

Output Receptacles

500

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

3 ea. 3/0

(3x95)

3 ea. 3/0

(3x95)

600

3/0 (95)

4/0 (120)

2 ea. 2/0

(2x70)

2 ea. 3/0

(2x95)

2 ea. 4/0

(2x120)

3 ea. 3/0

(3x95)

3 ea. 4/0

(3x120)

3 ea. 4/0

(3x120)

*

This chart is a general guideline and may not suit all applications. If cable overheats use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm

2

for metric use

S-0007-F−

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

Advertising
This manual is related to the following products: