7-4. Error Codes

1

Program CRC Error

2

Program Range Error

If either error code appears, reset

the display to factory settings as fol-

lows:
Press Parameter Select push but-

ton or turn welding power source

Off and back On. Change settings

and continue.

E R R O R

P r o g r a m

C R C

M e m o r y

W i l l

B e

R e s e t

P r e s s

P a r m.

S e l e c t

E R R O R

P r o g r a m

R a n g e

M e m o r y

W i l l

B e

R e s e t

P r e s s

P a r m.

S e l e c t

1

2

7-5. Troubleshooting

Trouble

Remedy

No weld output; unit completely inop-

erative.

Place line disconnect switch in On position (see Sections 4-6 and 4-7).

Check and replace line fuse(s), if necessary, or reset circuit breaker (see Sections 4-6 and 4-7).

Check for proper input power connections (see Sections 4-6 and 4-7).

No weld output; meter display On.

Input voltage outside acceptable range of variation (see Section 4-5).

Check, repair, or replace remote control.

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

If unit contains optional ground current sensor, excessive current in the ground circuit may have been

detected. Have electrician check input power circuit.

Erratic or improper weld output.

Check to make sure correct program is selected for welding wire and shielding gas used.

Use proper size and type of weld cable (see Section 4-2).

Clean and tighten all weld connections.

No 115 volts ac output at duplex recep-

tacle, Remote 14 receptacle.

Reset circuit breaker CB1 (see Section 4-4).

No 24 volts ac output at Remote 14 re-

ceptacle.

Reset circuit breaker CB2 (see Section 4-4).